mirror of
https://github.com/ergosteur/ergo-proxmox-scripts.git
synced 2026-10-28 13:00:37 -04:00
Add IPMI fan control scripts, reading credentials from conf/
ipmi-fancontrol.service pins the fans to a fixed speed on start and hands control back to the BMC's automatic curve on stop, to quiet the chassis. BMC credentials are read from conf/ipmi-fancontrol.conf, resolved relative to the scripts themselves so the tree stays self-contained whether it is run from a checkout or from /opt/ergosteur. See conf/ipmi-fancontrol.conf.example. Use ipmitool -E rather than -P so the password is passed via the environment instead of argv, where any local user could read it out of ps. docker-idrac.sh is the alternative temperature-aware controller. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5
parent
5a661d728f
commit
be5cc9b505
Executable
+11
@@ -0,0 +1,11 @@
|
||||
#!/bin/bash
|
||||
docker run -d \
|
||||
--name Dell_iDRAC_fan_controller \
|
||||
--restart=unless-stopped \
|
||||
-e IDRAC_HOST=local \
|
||||
-e FAN_SPEED=24 \
|
||||
-e CPU_TEMPERATURE_THRESHOLD=70 \
|
||||
-e CHECK_INTERVAL=60 \
|
||||
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=true \
|
||||
--device=/dev/ipmi0:/dev/ipmi0:rw \
|
||||
tigerblue77/dell_idrac_fan_controller:latest
|
||||
Reference in New Issue