Add IPMI fan control scripts, reading credentials from conf/
ipmi-fancontrol.service pins the fans to a fixed speed on start and hands control back to the BMC's automatic curve on stop, to quiet the chassis. BMC credentials are read from conf/ipmi-fancontrol.conf, resolved relative to the scripts themselves so the tree stays self-contained whether it is run from a checkout or from /opt/ergosteur. See conf/ipmi-fancontrol.conf.example. Use ipmitool -E rather than -P so the password is passed via the environment instead of argv, where any local user could read it out of ps. docker-idrac.sh is the alternative temperature-aware controller. Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
This commit is contained in:
co-authored by
Claude Opus 5
parent
5a661d728f
commit
be5cc9b505
@@ -0,0 +1,17 @@
|
|||||||
|
# Credentials for the BMC user driving ipmi-fancontrol-manual / ipmi-fancontrol-auto.
|
||||||
|
#
|
||||||
|
# Copy to conf/ipmi-fancontrol.conf next to the scripts and lock it down:
|
||||||
|
# cp conf/ipmi-fancontrol.conf.example conf/ipmi-fancontrol.conf
|
||||||
|
# chmod 0600 conf/ipmi-fancontrol.conf
|
||||||
|
#
|
||||||
|
# The scripts look for it relative to their own location, so this works both in a
|
||||||
|
# checkout and deployed at /opt/ergosteur. Override with IPMI_FANCONTROL_CONFIG.
|
||||||
|
|
||||||
|
IPMI_HOST=169.254.0.1
|
||||||
|
IPMI_USER=fancontrol
|
||||||
|
|
||||||
|
# Read by ipmitool -E, so it never appears in the process table.
|
||||||
|
IPMI_PASSWORD=changeme
|
||||||
|
|
||||||
|
# Fan speed applied in manual mode, as a raw hex byte (0x15 = 21%).
|
||||||
|
FAN_SPEED=0x15
|
||||||
Executable
+11
@@ -0,0 +1,11 @@
|
|||||||
|
#!/bin/bash
|
||||||
|
docker run -d \
|
||||||
|
--name Dell_iDRAC_fan_controller \
|
||||||
|
--restart=unless-stopped \
|
||||||
|
-e IDRAC_HOST=local \
|
||||||
|
-e FAN_SPEED=24 \
|
||||||
|
-e CPU_TEMPERATURE_THRESHOLD=70 \
|
||||||
|
-e CHECK_INTERVAL=60 \
|
||||||
|
-e DISABLE_THIRD_PARTY_PCIE_CARD_DELL_DEFAULT_COOLING_RESPONSE=true \
|
||||||
|
--device=/dev/ipmi0:/dev/ipmi0:rw \
|
||||||
|
tigerblue77/dell_idrac_fan_controller:latest
|
||||||
Executable
+25
@@ -0,0 +1,25 @@
|
|||||||
|
#!/bin/sh
|
||||||
|
# Hand fan control back to the BMC's automatic curve.
|
||||||
|
# Paired with ipmi-fancontrol-manual via ipmi-fancontrol.service.
|
||||||
|
set -eu
|
||||||
|
|
||||||
|
SCRIPT_DIR=$(CDPATH= cd -- "$(dirname -- "$0")" && pwd)
|
||||||
|
CONFIG=${IPMI_FANCONTROL_CONFIG:-$SCRIPT_DIR/conf/ipmi-fancontrol.conf}
|
||||||
|
|
||||||
|
if [ ! -r "$CONFIG" ]; then
|
||||||
|
echo "Error: cannot read $CONFIG" >&2
|
||||||
|
echo "Copy conf/ipmi-fancontrol.conf.example there and fill in the BMC credentials." >&2
|
||||||
|
exit 1
|
||||||
|
fi
|
||||||
|
|
||||||
|
. "$CONFIG"
|
||||||
|
|
||||||
|
: "${IPMI_HOST:?not set in $CONFIG}"
|
||||||
|
: "${IPMI_USER:?not set in $CONFIG}"
|
||||||
|
: "${IPMI_PASSWORD:?not set in $CONFIG}"
|
||||||
|
|
||||||
|
# ipmitool -E reads the password from IPMI_PASSWORD, keeping it out of argv.
|
||||||
|
export IPMI_PASSWORD
|
||||||
|
|
||||||
|
# Re-enable automatic fan control.
|
||||||
|
ipmitool -I lanplus -H "$IPMI_HOST" -U "$IPMI_USER" -E raw 0x30 0x30 0x01 0x01
|
||||||
Executable
+29
@@ -0,0 +1,29 @@
|
|||||||
|
#!/bin/sh
|
||||||
|
# Put the BMC into manual fan control and pin the fans to a fixed speed.
|
||||||
|
# Paired with ipmi-fancontrol-auto via ipmi-fancontrol.service.
|
||||||
|
set -eu
|
||||||
|
|
||||||
|
SCRIPT_DIR=$(CDPATH= cd -- "$(dirname -- "$0")" && pwd)
|
||||||
|
CONFIG=${IPMI_FANCONTROL_CONFIG:-$SCRIPT_DIR/conf/ipmi-fancontrol.conf}
|
||||||
|
|
||||||
|
if [ ! -r "$CONFIG" ]; then
|
||||||
|
echo "Error: cannot read $CONFIG" >&2
|
||||||
|
echo "Copy conf/ipmi-fancontrol.conf.example there and fill in the BMC credentials." >&2
|
||||||
|
exit 1
|
||||||
|
fi
|
||||||
|
|
||||||
|
. "$CONFIG"
|
||||||
|
|
||||||
|
: "${IPMI_HOST:?not set in $CONFIG}"
|
||||||
|
: "${IPMI_USER:?not set in $CONFIG}"
|
||||||
|
: "${IPMI_PASSWORD:?not set in $CONFIG}"
|
||||||
|
: "${FAN_SPEED:=0x15}"
|
||||||
|
|
||||||
|
# ipmitool -E reads the password from IPMI_PASSWORD, keeping it out of argv.
|
||||||
|
export IPMI_PASSWORD
|
||||||
|
|
||||||
|
# Disable the BMC's automatic fan curve.
|
||||||
|
ipmitool -I lanplus -H "$IPMI_HOST" -U "$IPMI_USER" -E raw 0x30 0x30 0x01 0x00
|
||||||
|
|
||||||
|
# Apply the fixed speed to all fans.
|
||||||
|
ipmitool -I lanplus -H "$IPMI_HOST" -U "$IPMI_USER" -E raw 0x30 0x30 0x02 0xff "$FAN_SPEED"
|
||||||
@@ -0,0 +1,9 @@
|
|||||||
|
[Unit]
|
||||||
|
Description=IPMI Fan Control silencing
|
||||||
|
[Service]
|
||||||
|
Type=oneshot
|
||||||
|
RemainAfterExit=yes
|
||||||
|
ExecStart=/opt/ergosteur/ipmi-fancontrol-manual
|
||||||
|
ExecStop=/opt/ergosteur/ipmi-fancontrol-auto
|
||||||
|
[Install]
|
||||||
|
WantedBy=multi-user.target
|
||||||