#!/bin/sh # Put the BMC into manual fan control and pin the fans to a fixed speed. # # This is the ad-hoc override; ipmi-fancontrol.service runs the temperature-aware # ipmi-fancontrol-daemon instead. Note that manual mode does not ramp under load. set -eu SCRIPT_DIR=$(CDPATH= cd -- "$(dirname -- "$0")" && pwd) CONFIG=${IPMI_FANCONTROL_CONFIG:-$SCRIPT_DIR/conf/ipmi-fancontrol.conf} if [ ! -r "$CONFIG" ]; then echo "Error: cannot read $CONFIG" >&2 echo "Copy conf/ipmi-fancontrol.conf.example there and fill it in." >&2 exit 1 fi . "$CONFIG" : "${IPMI_INTERFACE:=open}" : "${FAN_SPEED:=0x15}" ipmi() { if [ "$IPMI_INTERFACE" = "lanplus" ]; then ipmitool -I lanplus -H "$IPMI_HOST" -U "$IPMI_USER" -E "$@" else ipmitool -I open "$@" fi } if [ "$IPMI_INTERFACE" = "lanplus" ]; then : "${IPMI_HOST:?not set in $CONFIG}" : "${IPMI_USER:?not set in $CONFIG}" : "${IPMI_PASSWORD:?not set in $CONFIG}" # ipmitool -E reads the password from the environment, keeping it out of argv. export IPMI_PASSWORD fi # Disable the BMC's automatic fan curve, then apply the fixed speed to all fans. ipmi raw 0x30 0x30 0x01 0x00 ipmi raw 0x30 0x30 0x02 0xff "$FAN_SPEED"