Files
ergo-proxmox-scripts/nut
ergosteurandClaude Opus 5 6df3178cab Add /etc/nut reference configuration
Documents the target state for a host that owns a USB UPS and serves it to a
Synology, for hand-configuring a machine where running
setup-nut-synology.sh is not wanted. Verified byte-identical to what that
script generates, so the two cannot drift.

The [admin] password is the only real secret and ships as CHANGEME in both
files that must agree, upsd.users and the MONITOR line of upsmon.conf.

monuser/secret is committed literally. DSM hardcodes both and cannot be
configured otherwise, so they are published constants rather than
credentials, and the upsmon secondary role only permits reading status and
receiving shutdown notifications.

The example UPS serial is a placeholder rather than the real unit's.

Co-Authored-By: Claude Opus 5 <noreply@anthropic.com>
2026-08-06 17:02:19 +00:00
..
2026-08-06 17:02:19 +00:00

NUT configuration

Reference copies of /etc/nut for a host that owns a USB UPS and serves it to other machines — in particular to a Synology, whose DSM client connects with "UPS Type: Synology UPS Server".

setup-nut-synology.sh in the repo root generates all of these automatically by detecting the UPS with nut-scanner. Prefer running that. These files are here to document the target state and to hand-configure a host where you would rather not run the script.

Install by copying each file to /etc/nut/ without the .example suffix, then:

chown root:nut /etc/nut/*.conf /etc/nut/upsd.users
chmod 0640     /etc/nut/*.conf /etc/nut/upsd.users
systemctl enable --now nut-server nut-monitor
systemctl restart nut-driver@ups.service

What DSM requires

DSM's client cannot be configured, so three things are fixed:

  • the UPS must be named exactly ups — the [ups] section name in ups.conf
  • it logs in as monuser with the password secret, both hardcoded
  • upsd must listen on an address the Synology can reach

monuser / secret are therefore published constants, not credentials. The upsmon secondary role only permits reading status and receiving shutdown notifications; it cannot command the UPS.

What you must change

The [admin] password is a real secret and appears in two files that must agree: upsd.users and the MONITOR line of upsmon.conf. Both ship here as CHANGEME. Generate one with:

openssl rand -base64 18 | tr -d '/+=' | cut -c1-20

ups.conf is pinned to a specific unit by serial and product. Re-run setup-nut-synology.sh after swapping hardware, or drop those two lines to match any UPS of the same model.